PVC compounds for Wires & Cables – BS standards

RoHS COMPLIANT

PVC COMPOUNDS FOR ELECTRIC WIRES & CABLES

Technical Data Sheet

Standard: BS 6746

Property

Test Method

Unit

Specification

Application

 

 

Insulation

Insulation

Insulation

Sheathing

Sheathing

Insulation

Insulation

Sheathing

Sheathing

Standard

 

 

TI1

TI2

TI3

TM1

TM2

Type 2

Type 5

Type 6

Type 9

Density

ISO 1183

g/cm3

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

1.45 ÷ 1.55

Hardness

ASTM D 2240

Shore A

87 ÷ 90

80 ÷ 85

88 ÷ 90

87 ÷ 90

80 ÷ 85

90 ÷ 92

90 ÷ 92

80 ÷ 85

88 ÷ 90

Tensile strength

IEC 60811-1-1

N/mm2

≥ 12.5

≥ 10.0

≥ 15.0

≥ 12.5

≥ 10.0

≥ 18.5

≥ 12.5

≥ 6.0

≥ 12.5

Elongation

IEC 60811-1-1

%

≥ 125

≥ 150

≥ 150

≥ 125

≥ 150

≥ 125

≥ 125

≥ 125

≥ 150

Aging condition

IEC 60811-1-2

 

80°C x 7D

80°C x 7D

135° x 14D

80°C x 7D

80°C x 7D

-

135°C x 10D

-

100°C x 7D

    Tensile strength after aging

 

N/mm2

≥ 12.5

≥ 10.0

≥ 15.0

≥ 12.5

≥ 10.0

-

≥ 12.5

-

≥ 12.5

    Variation

 

%

≤ ±20

≤ ±20

≤ ±25

≤ ±20

≤ ±20

-

≤ ±25

-

≤ ±25

    Elongation after aging

 

%

≥ 125

≥ 150

≥ 150

≥ 125

≥ 150

-

≥ 125

-

≥ 150

    Variation

 

%

≤ ±20

≤ ±20

≤ ±25

≤ ±20

≤ ±20

-

≤ ±25

-

≤ ±25

Heat shock test 150°C x 1hr

IEC 60811-3-1

-

No crack

No crack

No crack

No crack

No crack

No crack

No crack

No crack

No crack

Loss of mass

Aging condition

IEC 60811-3-2

mg/cm2

≤ 2.0

80°C x 7D

≤ 2.0

80°C x 7D

≤ 1.5

115°C x 10D

≤ 2.0

80°C x 7D

≤ 2.0

80°C x 7D

≤ 2.0

80°C x 7D

≤ 1.5

115°C x 10D

≤ 2.0

80°C x 7D

≤ 1.5

100°C x 7D

Volume resistivity at 27°C

ASTM D257

Ω.cm

≥ 1013

≥ 1013

≥ 1014

-

-

≥ 1014

≥ 1014

-

-

Thermal stability at 200°C

IEC 60811-3-2

min

≥ 60

≥ 60

≥ 240

≥ 60

≥ 60

≥ 60

≥ 60

≥ 60

≥ 60

Low temperature test

IEC 60811-1-4

°C

-15

-15

-15

-15

-15

-15

-15

-15

-15

 

Footnotes:

  1. The density and hardness will be fixed when we get the requirements from each customer
  2. The property can be adjusted to be higher than the value in the standard if customer requires
  3. Lead-based grades are available upon request
  4. We have grades to meet the BS 7655 standard
  5. We have oil-resistant compounds for welding cables